ArlynGuard P Intrinsically Safe Platform Scales - From 500lb to 1000lb

Starting at $1899
Configure and Buy

Overview

The ArlynGuard P is built for Class I, II, and III Division 1 zones—ideal for drum weighing, batching, and material handling in flammable or explosive environments. With a low-profile platform, stainless steel load cells, and FM-approved safety components, it delivers precision and rugged reliability. Optional AC power and advanced connectivity available. View Configurations See more product details
Product Code Platform Size Capacity & Resolution Aluminum Stainless Steel
P5-16 16" x 18" x 1 7/8" 500 lbs x 0.1 lb $1899 $2199
P10-16 16" x 18" x 1 7/8" 1000 lbs x 0.2 lb $1899 $2199
P5-20 20" x 27" x 1 7/8" 500 lbs x 0.1 lb $1899 $2199
P10-20 20" x 27" x 1 7/8" 1,000 lbs x 0.2 lb $1899 $2199
P5-22 22" x 44" x 1 7/8" 500 lb x 0.1 lb $1999 $2449
P10-22 22" x 44" x 1 7/8" 1000 lb x 0.2 lb $1999 $2449
P5-27 27" x 60" x 1 7/8" 500 lb x 0.1 lb $2099 $2749
P10-27 27" x 60" x 1 7/8" 1000 lb x 0.2 lb $2199 $2849
P5-30 30" x 30" x 1 7/8" 500 lb x 0.1 lb $2099 $2529
P10-30 30" x 30" x 1 7/8" 1000 lb x 0.2 lb $2099 $2529
P5-36 36" x 36" x 1 7/8" 500 lb x 0.1 lb $2199 $2749
P10-36 36" x 36" x 1 7/8" 1000 lb x 0.2 lb $2199 $2749
P5-48 48" x 48" x 2 7/8" 500 lb x 0.1 lb $2529 $3049
P10-48 48" x 48" x 2 7/8" 1000 lb x 0.2 lb $2649 $3149

***CLICK ON THE PRICE TO AUTO-CONFIGURE YOUR SELECTED MODEL***

***CUSTOM SIZES & CAPACITIES ARE AVAILABLE. CALL US FOR PRICING & DELIVERY***

***CALL US FOR MULTIPLE PLATFORM REQUIREMENTS WITH SINGLE DISPLAY***

Details

Intrinsically Safe by Design

The ArlynGuard P series is built for hazardous industrial environments—certified for Class I, II, III Division 1 Groups A through G and Zone 0 conditions. Whether you’re operating in chemical plants, grain facilities, or flammable gas zones, it’s fully approved for both Division 1 and nonincendive Division 2 use.

Platform Built for Heavy Loads

With capacities up to 1000 lb and a low 1⅞" profile, ArlynGuard P makes drum weighing and materials handling safer and more efficient. The rugged welded platform is available in aluminum or optional stainless steel for corrosive environments.

No Moving Parts. Long-Term Reliability.

Arlyn’s in-house stainless steel load cells are matched and embedded directly into the frame—eliminating summation boards and minimizing failure points. The result is a stable, accurate scale with overload protection up to 150% of capacity.

Precision That Performs

All models deliver 0.1% full scale accuracy and feature an internal resolution of 1 part in 500,000—ideal for process control, inventory, and batch monitoring in regulated industries.

Battery or AC Power

Standard units operate up to 96 hours on included NiMH batteries (recharged in a safe area). For continuous use, an AC Powered System with an intrinsically safe Zener Barrier is available (Configuration #2).

Safe Area Integration (Optional)

For IIoT or automation needs, optional upgrades allow the scale to send weight data to external systems using MODBUS, Ethernet, Wi-Fi, or even direct-to-cloud and Google Sheets integration. Communication is routed through a Safe Area Display or barrier system for full compliance.

Custom Sizes Available

Standard platform sizes range from 16" x 18" to 48" x 48", with custom sizes and multi-platform systems built to order. Arlyn’s factory-direct model means your configuration can be tailored to your exact space and application.

Available Upgrades

The ArlynGuard B series is highly modular. Below are upgrade options available for various configurations, depending on whether components are located in a hazardous or safe area. Most advanced features require a Safe Area Display or Zener Barrier. Contact us to help configure the ideal system.

Power Options

Upgrade Configuration
AC Powered System (with Intrinsically Safe Zener Barrier) #2

Displays & Indicators

Upgrade Configuration
Additional Safe Area Display #3
Arlyn UpScale Touchscreen Indicator #3, #4
Full Featured MKE-5 Digital Indicator #3, #4
No Display Option (with analog output only) #5

Connectivity & Communication

Hazardous Area Outputs (with MKE-5-IS Display)
Upgrade Configuration
RS-422 #1, #2, #3, #4
RS-485 #2, #3, #4
Safe Area Outputs (requires Safe Area Display or Barrier)
Upgrade Configuration
Analog Output (4-20mA or 0-5VDC) #3, #4, #5
RS-232 Serial Port #2, #3, #4
USB Communication #2, #3, #4
Ethernet TCP/IP #2, #3, #4
Wi-Fi TCP/IP (w/ UpScale) #3, #4
Industrial Protocols (requires UpScale Display in Safe Area)
Upgrade Configuration
Modbus RTU/ASCII #3, #4
Modbus TCP #3, #4
EtherNet/IP #3, #4
PROFINET #3, #4

Printing & Barcode

Upgrade Configuration
Label / Card / Paper Printer (RS-232) #2, #3, #4
Bluetooth / USB Thermal Printer (58mm, UpScale) #3, #4
Barcode Scanning & Printing (UpScale) #3, #4

Control & Setpoints

Upgrade Configuration
Setpoints for Filling / Relays #1, #2, #3, #4
Alerts (Buzzer Alarm) #2, #3, #4
Light Tower (2- or 3-light) #2, #3, #4

Counting & Data Collection

Upgrade Configuration
Parts Counting #1, #2, #3, #4, #5
USB Data Logging (No PC Required) #2, #3, #4
AxChange Cloud Monitoring (UpScale only) #3, #4
Google Sheets Integration (UpScale only) #3, #4
Remote Indicator Software (PC) #2, #3, #4
Time & Date Output (MKE-5 only) #3, #4

Advanced Features (Safe Area Display Only)

Upgrade Configuration
Flow Rate Function + Alarms (UpScale) #3, #4
NEMA Stainless Steel Enclosure #3, #4
Remote Buttons (ZERO, TARE, PRINT, CYCLE) #2, #3, #4

Need Help Configuring?

Not sure what you need? Let us walk you through your setup. We'll help determine the best configuration based on your hazardous zone classification, power requirements, and data needs.

Specifications

The following specifications apply to all standard ArlynGuard P models unless otherwise noted. For resolution and capacity details, refer to the “Capacities & Platform Sizes” section above.

Performance

  • Accuracy: ±0.1% of full scale
  • Internal Resolution: 1 part in 500,000
  • Minimum Sampling Rate: 10 Hz
  • Tare / Zero Range: 100% of full scale
  • Display Speed: Adjustable from 0.1 to 0.5 seconds

Platform & Construction

  • Standard Heights: 1⅞" (2⅞" for 48" x 48" models)
  • Materials: Welded aluminum platform (standard) or optional stainless steel
  • Load Cells: In-house stainless steel load cells, heat-treated and precision-matched
  • Design: No summation board or moving parts; overload protection up to 150%
  • Available Sizes: 16" x 18" up to 48" x 48"; custom sizes available

Power Supply

  • Battery Powered (Standard):
    • 3 × 2600mAh NiMH AA rechargeable batteries
    • Includes spare set + external safe-area charger
    • Up to 96 hours of typical operation
  • AC Powered System (Optional):
    • Requires Intrinsically Safe Zener Barrier (Configuration #2)
    • Ideal for continuous-use environments

Display

  • Indicator Type: MKE-5-IS Digital Indicator (standard, intrinsically safe)
  • Display: 1" high graphical LCD digits
  • Mounting: Stainless steel swivel mount
  • Functions: Auto tare, keyboard tare, zero, net/gross toggle, unit conversion (lb, kg, oz, troy, etc.)
  • Memory: 100+ stored tare values

Calibration & Maintenance

  • Calibration: Factory calibrated
  • Field Calibration: Available via front panel (Safe Area Display required)
  • Maintenance: Minimal — no moving parts, solid-state electronics
  • Expected Lifespan: Designed for long-term use in hazardous industrial settings

Safety & Compliance

  • Certifications:
    • FM Approved (Approval Standards 3600, 3610, 3611, 3810)
    • Class I, II, III Division 1, Groups A–G
    • Class I, Zone 0, AEx ia IIC (T3 Ta=60°C)
    • Division 2 Approved (Nonincendive) for Groups A–G
  • Approved Components:
    • Digital Indicator: Model MKE-5-IS-a (b)
    • Load Cell Models: 620-300-IS, 520-5000L-IS, and others listed in official spec sheet

Documentation

Download the Full ArlynGuard P Spec Sheet (PDF)  

Frequently Asked Questions

What hazardous environments is the ArlynGuard P certified for?
The ArlynGuard P is certified for Class I, II, and III Division 1, Groups A–G, and Class I Zone 0 hazardous environments. It also meets Division 2 (nonincendive) requirements for flammable gases, dusts, and vapors. For full approval documentation, contact us or refer to the FM Approval Guide.
Can I use this scale around hydrogen, acetylene, or combustible dusts?
Yes. The scale is approved for Groups A through G, which include hydrogen (Group B), acetylene (Group A), and various dusts (Groups E–G). This broad certification ensures compatibility with most common industrial hazards.
What’s the difference between Division 1 and Division 2?
Division 1 covers areas where hazardous substances are present under normal operating conditions. Division 2 applies to areas where hazards are present only under abnormal conditions (e.g., a leak or equipment failure). The ArlynGuard P is certified for both, giving you maximum flexibility and compliance.
Is AC power available, or is it battery only?
Both options are available. The standard model includes rechargeable NiMH batteries with up to 96 hours of use. For continuous operation, an AC Powered System (Configuration #2) is available and includes an Intrinsically Safe Zener Barrier.
Can I integrate this with a PLC, SCADA system, or cloud software?
Yes. Optional Safe Area configurations support industrial protocols like Modbus, PROFINET, and EtherNet/IP, as well as modern outputs like Ethernet, Wi-Fi, USB, and direct integration with Google Sheets or AxChange Cloud Monitoring.
Is this scale suitable for chemical or corrosive environments?
Yes. The standard platform is aluminum, but stainless steel platform upgrades are available for environments involving harsh chemicals or frequent washdowns. All load cells are heat-treated stainless steel for corrosion resistance.
Can the ArlynGuard P be customized for a specific size or capacity?
Absolutely. In addition to our standard platform sizes (16" x 18" to 48" x 48"), we can build custom dimensions or adjust capacity to meet your exact application. Contact us for a custom quote.
Does it support part counting or flow rate monitoring?
Yes. Parts counting is supported across all configurations. Flow rate monitoring and alarm functions are available via the UpScale Touchscreen Display (Configuration #4) in a safe area setup.