ArlynGuard F Intrinsically Safe Floor Scales - From 2500lbs and above
Overview
The ArlynGuard F series delivers intrinsically safe, high-capacity floor scales engineered for Class I, II, and III Division 1 hazardous locations—certified for Groups A through G and Zone 0 environments. With load capacities up to 20,000 lb and rugged, heat-treated stainless steel load cells as a standard feature, ArlynGuard F is designed for abusive industrial settings like chemical plants, fuel facilities, and explosive dust environments. Optional AC-powered configurations, smart connectivity upgrades, and multiple platform sizes make it ideal for batch weighing, inventory control, and process automation—without the global-brand markup. View Configurations See more product detailsProduct Code | Capacity & Resolution | Platform Size | Steel | Stainless (-SS) |
---|---|---|---|---|
F25-33 | 2,500 lbs x 0.5 lb | 3' x 3' x 2 7/8" | $2519 | $3049 |
F50-33 | 5,000 lbs x 1 lb | 3' x 3' x 2 7/8" | $2519 | $3049 |
F25-44 | 2,500 lbs x 0.5 lb | 4' x 4' x 2 7/8" | $2619 | $3469 |
F50-44 | 5,000 lbs x 1 lb | 4' x 4' x 2 7/8" | $2619 | $3469 |
F100-44 | 10,000 lbs x 2 lb | 4' x 4' x 2 7/8" | $2829 | $3899 |
F200-44 | 20,000 lbs x 2 lb | 4' x 4' x 5 1/2" | $3249 | $4629 |
F50-55 | 5,000 lbs x 1 lb | 5' x 5' x 2 7/8" | $2829 | $4199 |
F50-46 | 5,000 lbs x 1 lb | 4' x 6' x 2 7/8" | $3149 | $4769 |
F100-57 | 10,000 lbs x 2 lb | 5' x 7' x 5 1/2" | $4099 | $5799 |
F100-68 | 10,000 lbs x 2 lb | 6' x 8' x 5 1/2" | $4519 | $6749 |
F200-57 | 20,000 lbx x 5 lb | 5' x 7' x 5 1/2" | $4519 | $6749 |
F200-68 | 20,000 lbs x 5 lb | 6' x 8' x 5 1/2" | $4939 | $7199 |
F200-79 | 20,000 lbs x 5 lb | 7' x 9' x 5 1/2" | $5669 | $9399 |
***CLICK ON THE PRICE TO AUTO-CONFIGURE YOUR SELECTED MODEL***
***CUSTOM SIZES & CAPACITIES ARE AVAILABLE. CALL US FOR PRICING & DELIVERY***
***CALL US FOR MULTIPLE PLATFORM REQUIREMENTS WITH SINGLE DISPLAY***
Details
Built for the Most Hazardous Environments
The ArlynGuard F series is certified for use in the most volatile industrial settings—Class I, II, III Division 1 Groups A through G and Class I, Zone 0 environments. This includes flammable gas zones (like hydrogen and acetylene), combustible dust areas, and ignitable fibers found in oil refineries, chemical plants, and agriculture processing facilities. Factory Mutual (FM) approvals cover all key components, including the MKE-5-IS Indicator and Arlyn’s proprietary load cells.Engineered for Abuse, Built to Outlast
Every ArlynGuard F model is equipped with industrial-grade, heat-treated stainless steel load cells—not aluminum or mild steel. These cells are protected in reinforced steel frame pockets designed to withstand forklift hits, pallet drops, and shock loading. The deck is a thick diamond steel plate with a durable, three-part epoxy coating. For harsh chemical or washdown environments, full stainless steel platforms are also available.High-Capacity Performance with Reliable Accuracy
With standard capacities ranging from 2,500 to 20,000 lb and a resolution as tight as 0.5 lb, ArlynGuard F is a workhorse for bulk weighing, pallet tracking, and drum batching. Internal resolution reaches 1 part in 500,000 with 0.1% accuracy across all models—ideal for production environments where safety and throughput matter more than ultra-fine precision.Battery or AC Power—Your Choice
Standard models operate on three rechargeable NiMH AA batteries with ~96 hours of use between charges (safe-area only). For continuous operation, an AC-powered version is available (Configuration #2), using an Intrinsically Safe Zener Barrier to maintain compliance in hazardous areas while eliminating downtime.Clear Displays, Flexible Controls
Each scale includes a stainless steel swivel-mount digital display with a large graphical LCD and 1” high digits. Functions include automatic tare, stored tare memory, net/gross toggling, and unit conversions (lb, kg, oz, etc.). Need a different setup? Choose from a touchscreen interface, remote display, or even a no-display configuration for PLC-integrated systems.Smart Integration Options (Safe Area Only)
Modern industrial operations often require data output and automation. ArlynGuard F supports optional safe-area communication outputs like:- USB, RS-232, Ethernet, Wi-Fi
- Modbus RTU/TCP, PROFINET, EtherNet/IP
- Cloud monitoring via AxChange, Google Sheets integration, Data logging with no PC required
- These options are available via safe area display configurations (see Configuration Guide below).
Built in the USA, Backed by Engineers
Manufactured in Long Island, NY, every ArlynGuard F scale is designed, built, and supported by Arlyn’s in-house engineering team. That means faster service, better customization, and no distributor markups—just rugged performance and expert support direct from the source.Available Upgrades
The ArlynGuard F series is highly modular. Below are upgrade options available for various configurations, depending on whether components are located in a hazardous or safe area. Most advanced features require a Safe Area Display or Intrinsically Safe Zener Barrier. Contact us to help configure the ideal system.Power Options
Upgrade | Configuration |
AC Powered System (with Intrinsically Safe Zener Barrier) | #2 |
Displays & Indicators
Upgrade | Configuration |
Additional Safe Area Display | #3 |
Arlyn UpScale Touchscreen Indicator | #3, #4 |
Full Featured MKE-5 Digital Indicator | #3, #4 |
No Display Option (with analog output only) | #5 |
Connectivity & Communication
Hazardous Area Outputs (with MKE-5-IS Display)
Safe Area Outputs (requires Safe Area Display or Barrier)
Upgrade | Configuration |
Analog Output (4-20mA or 0-5VDC) | #3, #4 |
RS-232 Serial Port | #2, #3, #4 |
USB Communication | #2, #3, #4 |
Ethernet TCP/IP | #2, #3, #4 |
Wi-Fi TCP/IP (w/ UpScale) | #3, #4 |
Industrial Protocols (requires UpScale Display in Safe Area)
Printing & Barcode
Upgrade | Configuration |
Label / Card / Paper Printer (RS-232) | #2, #3, #4 |
Bluetooth / USB Thermal Printer (58mm, UpScale) | #3, #4 |
Barcode Scanning & Printing (UpScale) | #4 |
Control & Setpoints
Upgrade | Configuration |
Setpoints for Filling / Relays | #1, #2, #3, #4 |
Alerts (Buzzer Alarm) | #3, #4 |
Light Tower (2- or 3-light) | #3, #4 |
Counting & Data Collection
Upgrade | Configuration |
Parts Counting | #1, #2, #3, #4 |
USB Data Logging (No PC Required) | #2, #3, #4 |
AxChange Cloud Monitoring (UpScale only) | #3, #4 |
Google Sheets Integration (UpScale only) | #3, #4 |
Remote Indicator Software (PC) | #2, #3, #4 |
Time & Date Output (MKE-5 only) | #3, #4 |
Advanced Features (Safe Area Display Only)
Upgrade | Configuration |
Flow Rate Function + Alarms (UpScale) | #3, #4 |
NEMA Stainless Steel Enclosure | #3, #4 |
Remote Buttons (ZERO, TARE, PRINT, CYCLE) | #2, #3, #4 |
No Display
Upgrade | Configuration |
4–20mA Amplifier (or 0–5V) – Safe Area Use Only | #5 |
Need Help Configuring?
Not sure what you need? Let us walk you through your setup. We'll help determine the best configuration based on your hazardous zone classification, power requirements, and data needs.Specifications
The following specifications apply to all standard ArlynGuard F models unless otherwise noted. For capacity and resolution details, refer to the “Capacities & Platform Sizes” section above.
Performance
- Accuracy: ±0.1% of full scale
- Internal Resolution: 1 part in 500,000
- Minimum Sampling Rate: 10 Hz
- Tare / Zero Range: 100% of full scale
- Display Speed: Adjustable from 0.1 to 0.5 seconds
Platform & Construction
- Platform Sizes: Ranges from 3' x 3' up to 7' x 9' (custom sizes available)
- Construction: Heavy-duty steel frame with diamond steel platform (standard); optional full stainless steel
- Coating: Three-part epoxy coating for rust, chemical, and abrasion resistance
- Load Cells: Heat-treated stainless steel (standard on all models)
- Design: Load cells protected in recessed pockets for shock and forklift resistance
- Washdown Rating: Not IP-rated; contact us for sealed enclosure options
Power Supply
Battery Powered (Standard)
- Uses (3) x 2600mAh NiMH AA rechargeable batteries
- Additional spare set + charger included
- Typical Operation: Up to 96 hours (varies by configuration)
- Note: Batteries must be changed/recharged in a safe area
AC Powered System (Optional – Configuration #2)
- Requires Intrinsically Safe Zener Barrier
- Ideal for continuous-use or fixed-installation environments
Display
- Type: Graphical LCD with 1” high digits, intrinsically safe.
- Mounting: Stainless steel swivel mount
- Functions: Auto tare, keyboard tare, net/gross toggle, multiple unit conversions (lb, kg, oz, troy, etc.)
- Memory: Over 100 stored tare locations
Calibration & Maintenance
- Calibration: Factory calibrated
- Field Calibration: Available via front panel (Safe Area Display required)
- Maintenance: Minimal due to solid-state load cell system (no moving parts)
- Expected Lifespan: Designed for long-term industrial use in hazardous environments
Integration & Data Options (Safe Area Configurations)
- USB, RS-232, Ethernet, Wi-Fi
- Modbus RTU / TCP, PROFINET, EtherNet/IP
- Google Sheets Integration
- AxChange Cloud Monitoring
- Analog Output: 4–20mA or 0–5VDC
- Compatible with SCADA, MES, and PLC systems
Safety & Compliance
- FM Approved Standards: 3600, 3610, 3611, 3810
- Approved Environments:
- Class I, II, III Division 1 Groups A–G
- Class I, Zone 0 AEx ia IIC (T3, Ta = 60°C)
- Class I, Division 2 (Nonincendive), Groups A–D
- Class II Division 2 Groups F–G
- Class III Division 2
- Approved Components:
- Digital Indicator: Model MKE-5-IS-a (b)
- Load Cells: 620-10-IS, 620-25-IS, 620-50-IS, 620-100-IS, 620-300-IS 520-2500-IS, 520-5000-IS, 520-5000L-IS, 520-10000L-IS 320-250-IS, 320-500-IS
Documentation
Download the Full ArlynGuard F Spec Sheet (PDF)Frequently Asked Questions
What hazardous environments is the ArlynGuard F certified for?
The ArlynGuard F is certified for Class I, II, and III Division 1 hazardous locations, including Groups A through G, as well as Class I, Zone 0 environments. It is also rated for nonincendive use in Division 2 locations. That includes flammable gases (like hydrogen and acetylene), combustible dusts (like carbon black or flour), and ignitable fibers. Contact us if you need help verifying a specific application or material.
Can I use this scale in a washdown or corrosive environment?
Yes. The standard platform includes a chemical-resistant epoxy coating, and an optional full stainless steel construction is available for more aggressive washdown or corrosive settings. Contact us to confirm the best option for your environment.
What’s the benefit of the AC-powered option?
Our AC-powered system (Configuration #2) includes an Intrinsically Safe Zener Barrier and is ideal for continuous-use environments where battery swapping is inconvenient or not feasible. It allows the scale to be permanently powered from a safe area.
Can I integrate this scale with a PLC or SCADA system?
Yes. ArlynGuard F supports multiple industrial protocols including Modbus, PROFINET, EtherNet/IP, and analog outputs (4–20mA or 0–5VDC). Integration is available through Safe Area configurations with the appropriate display and barrier setup.
Does it support wireless or cloud-based data logging?
Yes. With the UpScale Display in a Safe Area (Configuration #4), you can enable Wi-Fi, log data directly to Google Sheets, or monitor in real time via Arlyn’s AxChange cloud platform.
How long does the battery-powered version last?
Typical operation is up to 96 hours per charge. Each unit includes rechargeable NiMH batteries and a spare set with a charger. Batteries must be changed and recharged in a designated safe area.
Can I get a custom platform size or capacity?
Yes. Since all ArlynGuard F scales are manufactured in-house, we offer a wide range of custom platform sizes and weight capacities. Let us know your exact requirements and we’ll design a system to match.
Can I operate the scale without a display?
Yes. Configuration #5 allows for a no-display option with an analog output. This setup is ideal for customers who need to route weight data directly to another system without using a local display.
How accurate is the ArlynGuard F?
All models offer ±0.1% of full-scale accuracy with internal resolution up to 1 part in 500,000. For example, a 5,000 lb capacity scale delivers 5 lb accuracy—ideal for bulk, pallet, and drum applications. For ultra-precise needs, consider the ArlynGuard S series.