ArlynGuard C Intrinsically Safe Cylinder Scales - Capacities From 60lb to 400lb
Overview
The ArlynGuard C is a specialized industrial scale designed for weighing pressurized cylinders in Class I, II, and III Division 1 hazardous environments. Its low-profile stainless steel platform and intrinsically safe electronics make it ideal for gas tanks, chemical drums, and corrosive materials in areas with flammable vapors, explosive dust, or reactive compounds. Whether monitoring chlorine at a water treatment plant or tracking CO₂ in a bottling facility, the ArlynGuard C delivers precision and safety, with optional AC power, cloud connectivity, and multi-display configurations for continuous operation. See more product detailsProduct Code | Capacity & Resolution | Platform Size | Price | |
---|---|---|---|---|
C6 | 60 lbs x 0.02 lb 27 kg x 10 g | 9.25" x 9.25", Optional 12" and 14" | $1,799 | Buy Now |
C10 | 100 lbs x 0.02 lb 45 kg x 10 g | 9.25" x 9.25", Optional 12" and 14" | $1,799 | Buy Now |
C30 | 300 lbs x 0.1 lb 136 kg x 50 g | 9.25" x 9.25", Optional 12" and 14" | $1,799 | Buy Now |
C40 | 400 lbs x 0.1 lb 181 kg x 50 g | 9.25" x 9.25", Optional 12" and 14" | $1,899 | Buy Now |
***CUSTOM SIZES & CAPACITIES ARE AVAILABLE. CALL US FOR PRICING & DELIVERY***
***CALL US FOR MULTIPLE PLATFORM REQUIREMENTS WITH SINGLE DISPLAY***
Details
Designed specifically for cylindrical and pressurized tank applications, ArlynGuard C features a compact, low-profile platform that ensures stable and accurate readings—even when loads are off-center or awkwardly shaped. The ultra-sensitive sensors deliver resolutions as precise as 0.02 lb with internal resolution up to 1 part in 500,000, making it ideal for real-time monitoring of gas usage or chemical depletion.Certified Intrinsically Safe
Every ArlynGuard C scale is certified for use in hazardous environments—Class I, II, III Division 1, Groups A through G, and Zone 0 conditions. It meets Factory Mutual (FM) approval standards and includes components rated for nonincendive operation in Division 2 environments.Built for Durability
Constructed with corrosion-resistant materials including heat-treated stainless steel load cells and a rugged aluminum frame, the platform supports tank sizes up to 400 lbs and is available in 9.25", 12", or 14" square configurations. Custom platforms and all-stainless construction are available for challenging chemical environments.Flexible Power & Display Options
Choose between:- Battery Operation (up to 96 hours of use, safe-area recharge)
- New AC Powered System with intrinsically safe Zener Barrier (Configuration #2) for continuous use
Modern Integration, Optional
Optional connectivity allows the ArlynGuard C to integrate directly into SCADA or MES systems with support for:- Modbus, RS-232/422/485, Ethernet, Wi-Fi
- USB data logging with Google Sheets integration
- AxChange Cloud Monitoring for live tracking and alerts
Available Upgrades
The ArlynGuard C series is highly modular and supports a wide range of configurations depending on where components are located—hazardous or safe area—and whether your setup requires local display, advanced connectivity, or continuous power. Most advanced features require a Safe Area Display or Intrinsically Safe Zener Barrier. Contact us to help configure the ideal system.Power Options
Displays & Indicators
Upgrade | Configuration |
Additional Safe Area Display | #3, #4 |
Arlyn UpScale Touchscreen Indicator | #3, #4 |
Full Featured MKE-5 Digital Indicator | #3, #4 |
No Display Option (with analog output only) | #5 |
Connectivity & Communication
Hazardous Area Outputs (with MKE-5-IS Display)
Safe Area Outputs (requires Safe Area Display or Barrier)
Upgrade | Configuration |
Analog Output (4–20mA or 0–5VDC) | #2, #3, #4 |
RS-232 Serial Port | #2, #3, #4 |
USB Communication | #2, #3, #4 |
Ethernet TCP/IP | #2, #3, #4 |
Wi-Fi TCP/IP (UpScale only) | #3, #4 |
Industrial Protocols (requires UpScale Display in Safe Area)
Upgrade | Configuration |
Modbus RTU / ASCII | #3, #4 |
Modbus TCP | #3, #4 |
EtherNet/IP | #3, #4 |
PROFINET | #3, #4 |
Printing & Barcode
Upgrade | Configuration |
Label / Card / Paper Printer (RS-232) | #2, #3, #4 |
Bluetooth / USB Thermal Printer (58mm, UpScale) | #3, #4 |
Barcode Scanning & Printing (UpScale) | #3, #4 |
Control & Setpoints
Upgrade | Configuration |
Setpoints for Filling / Relays | #1, #2, #3, #4 |
Alerts (Buzzer Alarm) | #3, #4 |
Light Tower (2- or 3-light) | #3, #4 |
Counting & Data Collection
Upgrade | Configuration |
Parts Counting | #1, #2, #3, #4 |
USB Data Logging (No PC Required) | #2, #3, #4 |
AxChange Cloud Monitoring (UpScale only) | #3, #4 |
Google Sheets Integration (UpScale only) | #3, #4 |
Remote Indicator Software (PC) | #2, #3, #4 |
Time & Date Output (MKE-5 only) | #3, #4 |
Advanced Features (Safe Area Display Only)
Upgrade | Configuration |
Flow Rate Function + Alarms (UpScale) | #3, #4 |
NEMA Stainless Steel Enclosure | #3, #4 |
Remote Buttons (ZERO, TARE, PRINT, CYCLE) | #2, #3, #4 |
Need Help Configuring?
Not sure what you need? Let us walk you through your setup. We'll help determine the best configuration based on your hazardous zone classification, power requirements, and data needs.Specifications
The following specifications apply to all standard ArlynGuard C models unless otherwise noted. For resolution and capacity details, refer to the “Capacities & Platform Sizes” section.
Performance
- Accuracy: ±0.1% of full scale
- Internal Resolution: 1 part in 500,000
- Minimum Sampling Rate: 10 Hz
- Tare/Zero Range: 100% of full scale
- Display Speed: Adjustable from 0.1 to 0.5 seconds
Platform & Construction
- Standard Size: 9.25" x 9.25"
- Optional Sizes: 12" x 12", 14" x 14", or custom (as small as 4" x 4")
- Materials: Stainless steel platform, heat-treated stainless steel load cells, rugged aluminum housing
- Design: Ultra-low profile for easy cylinder loading and improved stability
- IP Rating: Not washdown-rated; contact us for sealed enclosure options
Power Supply
- Battery Power (Standard):
- (3) x 2600mAh NiMH AA rechargeable batteries
- Spare set + charger included
- Batteries must be changed in a safe area
- Typical operation: ~96 hours (dependent on features)
- AC Power (Optional):
- Requires Zener Barrier (Configuration #2)
- Ideal for continuous use or always-on operations
Display
- Indicator Type: 1” high graphical LCD digits
- Functions: Auto tare, keyboard tare, zero, net/gross toggle, unit conversion (lb, kg, oz, troy, etc.)
- Mounting: Stainless steel swivel mount
- Memory: 100+ tare locations
Calibration & Maintenance
- Calibration: Factory calibrated
- Field Calibration: Available via front panel (Safe Area Display required)
- Maintenance: Minimal due to solid-state “no moving parts” design
Safety & Compliance
- Certifications:
- FM Approved (Standards 3600, 3610, 3611, 3810)
- Class I, II, III Division 1 Groups A–G
- Class I, Zone 0 AEx ia IIC (T3, Ta=60°C)
- Division 2 approval for nonincendive use
- Approved Components:
- Digital Indicator: Model MKE-5-IS-a (b)
- Load Cells: Models 620-10-IS to 520-10000L-IS
Documentation
Download the Full ArlynGuard C Spec Sheet (PDF)Frequently Asked Questions
What environments is the ArlynGuard C certified for?
The ArlynGuard C is certified for use in Class I, II, and III Division 1 hazardous environments, including Groups A through G. It also meets standards for Class I, Zone 0 areas with flammable gases and vapors, as well as dusty or explosive atmospheres like those found in labs, refineries, and chemical plants.
Can I use this scale to monitor gas cylinder usage?
Yes. The ArlynGuard C is purpose-built for weighing compressed gas cylinders with precision and safety. It supports capacities from 60 to 400 lbs and offers high-resolution readings ideal for monitoring cylinder contents.
What’s the benefit of upgrading to AC power?
The new AC power configuration (Configuration #2) supports continuous use without the need to recharge batteries—ideal for operations that require constant monitoring or high throughput. It also simplifies integration with permanent control systems.
Do I need a display in the hazardous area?
Not necessarily. You can configure the scale with a Safe Area Display or even choose a No Display option if you’re routing data directly to a PLC, SCADA system, or software interface. Contact us to match your setup with the right configuration.
How do I export weight data or integrate with other systems?
Safe Area configurations support outputs like USB, Modbus, Ethernet, and even Wi-Fi. We offer Google Sheets integration, USB data logging (no PC required), and SCADA-ready protocols via our optional UpScale Indicator.
Is this scale suitable for corrosive or wet environments?
The standard platform is made from rugged stainless steel and aluminum. For highly corrosive or wet areas, we offer an upgrade to a full NEMA-rated stainless steel enclosure. Contact us with details about your environment to confirm compatibility.
Can the scale count parts or track flow rate?
Yes. Parts counting is included by default. If you're dosing gases or tracking depletion rates, the optional UpScale Indicator adds a Flow Rate Function with alarms, ideal for process control and alerts.