REST API and Modbus for SAW Scale Connections

Use the Web API when your software needs weight readings through HTTP and JSON. Use Modbus when a PLC or SCADA system expects mapped scale data. An Arlyn SAW scale with the appropriate UpScale communication options can serve either route, and the Web API can operate alongside a selected supported PLC interface.

The practical starting point is the equipment receiving the weight. A computer application and a machine controller may use the same weighing station for different tasks. UpScale provides the configured connections, while the SAW scale measures the load.

Which connection fits the weighing station?

A computer-based weighing station can collect readings directly through the Web API. A station already connected to a PLC can supply the controller through Modbus. Start with the receiving system and the action that needs the reading, then choose how that system will collect and use the result.

Choose the route to your receiving system
Connection How it fits the station
Web API: application GET Your application requests a reading; UpScale replies with JSON. Useful when the application chooses the capture moment or refreshes an on-screen weight.
Web API: JSON delivery UpScale sends JSON by HTTP POST to a configured receiver, periodically or through PRINT. Useful when the scale initiates collection.
Modbus A PLC or other client requests mapped scale data. Fits a station whose automation system already uses Modbus and its data map.

Example: an operator checking ingredient quantities from a computer screen can use an application that requests the weight when the check is saved. At another station, the operator can press PRINT at UpScale to send the reading to the receiving application. These are two forms of Web API communication using HTTP and JSON, available over Ethernet or Wi-Fi.

The Web API also supports remote zero, applying or clearing tare, and toggling available units or gross/net mode. Those control POST requests go to UpScale; scale-originated JSON delivery goes to your receiver. The industrial scale API integration guide covers connection settings and examples, and the HTTP API reference lists the exact resources and commands.

Use Modbus in an existing control system

Modbus fits a weighing station when the machine controller or plant software already reads devices through a Modbus data map. UpScale acts as the responding device: the PLC or other client requests the supported data. The connection uses the configured serial interface or a network, depending on the selected Modbus mode.

UpScale supports Modbus RTU/ASCII through serial communication and Modbus TCP through a network connection. The client needs the matching mode, connection settings and data map. That map identifies the numbered data areas the client reads and explains how to interpret their values.

Example: a dispensing machine already uses a PLC to coordinate its weighing step. Reading the SAW station through Modbus brings the weight into that existing control program. The PLC program decides how to use the reading within the machine sequence.

  • Select the Modbus mode and its matching physical connection.
  • Use the documented data areas and value formats in the client program.
  • Assign zero and tare actions to the appropriate operator or application step.

The UpScale manual’s Modbus section provides configuration and data-area details. For the wider choice of automation interfaces, use the PLC communication guide; the Modbus utilities provide related setup resources.

Use software and PLC connections together

An equipped UpScale can run its Web API alongside the selected Modbus TCP, EtherNet/IP or PROFINET option. This allows the PLC to collect weighing data for the machine while a separate application collects readings for a display or report. Each system uses the connection and data format configured for it.

For example, the PLC can read the weighing station during dispensing while a computer application records the completed quantity. The application associates that result with a job or container and adds the capture time. The ERP and MES integration article follows that production-record workflow.

In an ArlynGuard S installation, the weighing equipment can be in the classified area while UpScale provides advanced communication from the safe area. The ArlynGuard S configuration guide shows the display locations and available connections for each arrangement.

Frequently Asked Questions

Does a scale need SAW technology to use the Web API?

No. The Web API is an UpScale option and is available with other equipped Arlyn scales. SAW supplies the weighing technology; the selected UpScale options provide the software and PLC connections.

Can I still use GET to retrieve weights?

Yes. An application can request a reading when it needs one or poll UpScale to update a display. Scale-originated JSON provides another way to collect readings, periodically or when the operator presses PRINT.

Does Modbus TCP use HTTP and JSON?

No. Modbus TCP exchanges mapped data over a network connection. An HTTP application uses the Web API and its JSON responses. Each connection needs software that understands its protocol and data format.

Can Web API and a PLC interface operate concurrently?

Yes. An equipped UpScale can run the Web API alongside the selected Modbus TCP, EtherNet/IP or PROFINET option. A PLC and a software application can therefore collect weighing data from the same system.

Where do batch totals, timestamps and job IDs come from?

For the documented HTTP weight response, UpScale supplies the reading and weighing settings. The receiving application adds capture times and job information and calculates accumulated totals for its own records.

How does the connection work in a hazardous area?

ArlynGuard S configurations separate hazardous-area weighing equipment from safe-area communication equipment. The specified advanced configuration places UpScale in the safe area, where it provides the supported software and industrial-protocol connections.

Connect your SAW weighing station

Explore Ultra Precision SAW scales or compare UpScale indicator options and pricing for your software or PLC connection.

Discuss Your Scale Integration

Call 800-645-4301.