Intrinsically Safe Drum Scales | ArlynGuard D | Arlyn Scales Intrinsically Safe Drum Scales | ArlynGuard D | Arlyn Scales

Explosive Environment Scales – ArlynGuard D

Availability: Ships in 12–20 business days. Call for urgent orders.
Product Code: explosive-environment-scale-d

$2,409.00

Options Total: $ 0


Specifications


Output

Printing


Setpoint Control

Parts Counting

Data Collection

Extras


Total Price: $ 2409

Intrinsically Safe Drum Weighing for Hazardous Locations
The ArlynGuard D intrinsically safe drum scale combines a low-profile industrial weighing platform, included loading ramp and ArlynGuard hazardous-location weighing electronics for weighing 55-gallon drums, chemical containers and similar vessels in classified industrial environments.

The ArlynGuard D intrinsically safe drum scale gives facilities a purpose-built way to weigh drums where flammable gases, vapors, combustible dust or other hazardous materials may be present. Rather than adapting a general-purpose platform scale to drum handling, Arlyn combines its intrinsically safe ArlynGuard weighing system with a low-profile ramped platform developed specifically for rolling drums and containers onto the weighing surface.

Standard D-series models provide 500 lb or 1,000 lb capacities with either a 30″ x 30″ or 36″ x 36″ platform. In addition, every standard configuration includes a matching 15″-deep loading ramp. Customers can choose aluminum or stainless steel construction to suit different industrial and environmental requirements.

ArlynGuard D Models, Capacities and Platform Sizes

Choosing the correct ArlynGuard D starts with the maximum loaded drum weight and the required platform size. For example, the 500 lb models provide 0.1 lb readability, while the 1,000 lb models provide 0.2 lb readability. Both capacities are available with either platform size.

ArlynGuard D Models and Pricing
Product Code Platform & Ramp Capacity & Readability Aluminum Stainless Steel (-SS)
D5-30 30″ x 30″ x 1 7/8″
Ramp: 30″ x 15″
500 lb x 0.1 lb $2,409 $3,129
D10-30 30″ x 30″ x 1 7/8″
Ramp: 30″ x 15″
1,000 lb x 0.2 lb $2,409 $3,129
D5-36 36″ x 36″ x 1 7/8″
Ramp: 36″ x 15″
500 lb x 0.1 lb $2,569 $3,429
D10-36 36″ x 36″ x 1 7/8″
Ramp: 36″ x 15″
1,000 lb x 0.2 lb $2,569 $3,429

Designed for Drum Weighing in Hazardous Areas

Industrial facilities routinely use drums for chemicals, solvents, coatings, ingredients, waste materials and other process materials. When those materials create a hazardous classified environment, standard electrical weighing equipment may not be suitable. Therefore, the weighing system must match the requirements of the classified area.

ArlynGuard D provides a dedicated hazardous-location drum weighing solution. Its platform measures only 1 7/8″ high, and the included ramp lets operators roll compatible drums onto the scale instead of lifting them onto an elevated platform.

In addition, the 30″ and 36″ platform sizes accommodate common industrial drums while providing useful space for pails, containers and other vessels that fit safely within the selected platform and capacity.

Intrinsically Safe ArlynGuard System

ArlynGuard D belongs to the ArlynGuard family of intrinsically safe weighing systems. The system supports hazardous classified applications including:

  • Class I, II and III, Division 1, Groups A, B, C, D, E, F and G
  • Class I, Zone 0, AEx ia IIC (T3 Ta=60C)
  • Class I, Division 2, Groups A, B, C and D
  • Class II, Division 2, Groups F and G
  • Class III, Division 2 indoor hazardous classified locations

Arlyn builds these systems around approved intrinsically safe weighing components, including the MKE-5-IS digital weight indicator system and applicable FM-approved load cell models. However, the exact equipment configuration must match the hazardous-area classification and installation requirements.

For a detailed overview of the available system layouts, see ArlynGuard Intrinsically Safe Scale Configurations.

Low-Profile Platform with Included Loading Ramp

Moving a loaded 55-gallon drum onto a conventional platform can be difficult, especially when the weighing surface sits several inches above the floor. ArlynGuard D addresses this problem with a 1 7/8″ high platform and matching 15″-deep ramp.

As a result, operators can move compatible drums between the floor and weighing platform more easily. Arlyn matches the ramp width to the selected platform: the 30″ platform uses a 30″ x 15″ ramp, while the 36″ platform uses a 36″ x 15″ ramp.

This arrangement works particularly well for drum filling, batching, material consumption and inventory-monitoring applications where operators repeatedly move drums onto and off the scale.

Aluminum or Stainless Steel Construction

Customers can order ArlynGuard D with either an aluminum or stainless steel platform and ramp. Aluminum provides a durable industrial weighing platform at a lower system cost. Stainless steel, meanwhile, offers another construction choice for applications where additional corrosion resistance or environmental durability is preferred.

Multiple stainless steel load sensors measure the load directly through the scale platform. Consequently, the system does not depend on mechanical pivot and lever assemblies to transfer the drum weight to a single sensor.

High Accuracy Industrial Drum Weighing

Standard ArlynGuard D models provide ±0.1% of full-scale accuracy. The 500 lb models display weight in 0.1 lb increments, whereas the 1,000 lb models display weight in 0.2 lb increments.

Importantly, readability and accuracy describe different aspects of scale performance. Readability identifies the smallest weight increment shown by the indicator. Accuracy, by contrast, describes how closely the measured result represents the correct weight under the specified conditions.

Therefore, users should select enough capacity for the fully loaded drum, container and practical operating margin while also considering the displayed readability required by the process.

Battery Operation or Continuous AC Power

Standard ArlynGuard configurations use rechargeable NiMH batteries, allowing the scale to operate without a conventional AC power connection in the hazardous area. The MKE-5-IS uses three supplied 2600 mAh NiMH AA batteries and typically provides approximately 96 hours of operation, depending on the installed options and operating conditions.

Users must change and recharge the batteries in a safe area.

Alternatively, facilities that require continuous operation can select an AC-powered system that uses an intrinsically safe safety barrier. See ArlynGuard Configuration #2 for additional information.

Available ArlynGuard D Upgrades

ArlynGuard D can serve as a straightforward battery-powered drum scale. However, facilities can also connect it to safe-area displays, data systems, printers, alarms, PLCs and process-control equipment. The available functions depend on the selected ArlynGuard configuration.

Power and Safe-Area Displays

For continuous installations, a safety barrier can provide the required separation between hazardous-area equipment and safe-area power or electronics. In addition, customers can add a secondary MKE-5 or Arlyn UpScale display in the safe area when the application requires more advanced communication, workflow or data functions.

Communication and Process Integration

Depending on the selected configuration, ArlynGuard D can communicate with safe-area equipment through serial, analog or network interfaces. Furthermore, supported UpScale configurations can extend the system to industrial protocols and connected data workflows.

ArlynGuard D Available Upgrades
Upgrade Available Options Configuration
Additional Safe-Area Display #3
Power Supply AC-powered system with intrinsically safe safety barrier #2
Hazardous-Area Communication RS-422 and RS-485 #1,
#2
Safe-Area Communication & Outputs
  • 4-20 mA or voltage analog output
  • RS-232 serial communication
  • USB virtual serial communication
  • Ethernet TCP/IP
  • Wi-Fi TCP/IP with UpScale
  • Modbus RTU / ASCII with UpScale
  • Modbus TCP with UpScale
  • EtherNet/IP with supported UpScale configurations
  • PROFINET with supported UpScale configurations
#2,
#3,
#4
Printing & Barcode Output #2,
#3,
#4
Setpoint & Process Control
  • Programmable weight setpoints
  • AC/DC relay control
  • Buzzer alarms
  • Two- or three-color light towers
  • Filling and batching control applications
#2,
#3,
#4
Parts Counting Parts-counting operation All supported configurations
Data Collection
  • Time and date output with supported MKE-5 configurations
  • USB data logging
  • Remote Indicator software
  • Google Sheets data logging with supported UpScale configurations
  • AxChange remote monitoring with supported UpScale configurations
#2,
#3,
#4
Additional Safe-Area Functions
  • Flow-rate monitoring and alarms with UpScale
  • NEMA stainless steel enclosure
  • Remote ZERO, TARE, PRINT and CYCLE controls
#3,
#4
No-Display Configuration 4-20 mA, 0-5 V or 1-5 V amplifier for safe-area use #5

Data, Printing and Control Options

For applications that require more than local weight display, the safe-area configuration can extend ArlynGuard D into a larger process system. For instance, a facility can collect weighing records, send weight data to a PLC or use setpoints and relays during a drum-filling operation. Likewise, supported UpScale configurations can add printing, barcode workflows and network-based data functions.

Need help selecting an ArlynGuard configuration?

The correct configuration depends on the hazardous-area classification, display location, power source and required communication or control interfaces. Therefore, contact Arlyn Scales if you need help selecting an ArlynGuard D system.

ArlynGuard D Technical Specifications

The following specifications summarize the standard D-series platform and indicator configurations. However, optional communication, control and safe-area equipment can change the complete system configuration.

Standard ArlynGuard D Specifications
Standard Capacities 500 lb and 1,000 lb
Displayed Readability 0.1 lb at 500 lb capacity; 0.2 lb at 1,000 lb capacity
Accuracy ±0.1% of full scale
Tare / Zero Range 100% of full scale
Display Speed Adjustable from 0.1 to 0.5 seconds
Standard Platform Sizes 30″ x 30″ or 36″ x 36″
Platform Height 1 7/8″
Included Ramp 30″ x 15″ or 36″ x 15″, matched to platform width
Construction Aluminum or optional stainless steel platform and ramp
Standard Indicator MKE-5-IS intrinsically safe digital weight indicator system
Indicator Display 1″ high graphical LCD weight digits
Indicator Dimensions Approximately 8″ W x 4.8″ H x 2.5″ D
Standard Power Three supplied 2600 mAh rechargeable NiMH AA batteries
Typical Battery Operation Approximately 96 hours depending on options and operating conditions
Optional Continuous Power AC-powered configuration using an intrinsically safe safety barrier
Hazardous-Location Classification Class I, II and III, Division 1, Groups A-G; Class I, Zone 0, AEx ia IIC (T3 Ta=60C), with additional Division 2 classifications as applicable to the approved configuration

FM-Approved ArlynGuard Components

Arlyn uses approved components in ArlynGuard weighing systems, including the MKE-5-IS-a (b) Digital Weight Indicator System and applicable intrinsically safe load cells.

Approved Arlyn load-cell models include 620-300-IS, 620-100-IS, 620-50-IS, 620-25-IS, 620-10-IS, 520-10000L-IS, 520-5000L-IS, 520-5000IS, 520-2500-IS, 520-1250-IS, 320-500-IS and 320-250-IS.

Factory Mutual (FM) has approved these components under applicable Approval Standards 3600, 3610, 3611 and 3810. Nevertheless, the approval and installation requirements for the complete weighing system depend on the exact ArlynGuard configuration and classified location.

For general regulatory information about electrical equipment in hazardous classified locations, see OSHA 29 CFR 1910.307 – Hazardous (Classified) Locations.

ArlynGuard D vs. ArlynGuard P

ArlynGuard D and ArlynGuard P use the same broader ArlynGuard intrinsically safe system architecture. However, they serve different material-handling requirements.

Choose ArlynGuard D when operators regularly roll drums or similar containers onto and off the scale. Its low-profile platform and included ramp make it the more appropriate drum-weighing configuration.

By comparison, choose the ArlynGuard P intrinsically safe platform scale when the application needs a more general-purpose hazardous-location platform rather than a drum-specific loading arrangement.

Finally, if the application does not require intrinsically safe equipment, see Arlyn’s standard industrial drum scales with loading ramps.

Typical ArlynGuard D Applications

Because the ArlynGuard D combines hazardous-location weighing with convenient drum loading, it fits a range of industrial processes, including:

  • 55-gallon drum weighing
  • Chemical drum inventory monitoring
  • Drum filling and batching
  • Solvent and coating production
  • Material consumption monitoring
  • Hazardous-material processing
  • Waste and recovery operations
  • Industrial process containers
  • Safe-area PLC and process-system integration

Frequently Asked Questions

Drum Scale Selection

What is an intrinsically safe drum scale?
An intrinsically safe drum scale uses a weighing architecture intended for specified hazardous classified locations while limiting electrical energy according to the approved protection method. ArlynGuard D combines this approach with a low-profile platform and loading ramp for industrial drums.
Can the ArlynGuard D weigh a 55-gallon drum?
Yes. Arlyn configured the D-series specifically for industrial drum weighing. Standard models use 30″ x 30″ or 36″ x 36″ platforms and provide either 500 lb or 1,000 lb capacity.
Does the ArlynGuard D include a loading ramp?
Yes. Every standard model includes a 15″-deep loading ramp matched to the platform width. The 30″ platform includes a 30″ x 15″ ramp, while the 36″ platform includes a 36″ x 15″ ramp.
Is ArlynGuard D available in stainless steel?
Yes. Customers can select either aluminum or stainless steel construction for each standard D-series capacity and platform size.
What capacities are available?
Arlyn offers standard D-series configurations at 500 lb x 0.1 lb and 1,000 lb x 0.2 lb with either a 30″ x 30″ or 36″ x 36″ platform.

Hazardous-Area Operation and Integration

What is the difference between an intrinsically safe drum scale and an explosion-proof scale?
The terms sometimes appear together in product searches, but they describe different hazardous-location protection approaches. Intrinsic safety limits electrical energy according to the approved system design. Therefore, users should select equipment according to the actual hazardous-area classification and installation requirements.
Can the ArlynGuard D operate continuously without batteries?
Yes. Standard systems use rechargeable batteries. Alternatively, an appropriate ArlynGuard configuration can provide continuous AC power through an intrinsically safe safety barrier.
Can drum weight be sent to a PLC or control system?
Yes. Depending on the selected safe-area configuration, the system can provide analog, serial, Ethernet and supported industrial-network interfaces. In addition, compatible UpScale configurations can support Modbus, EtherNet/IP and PROFINET.
Can the ArlynGuard D be used for filling drums?
Yes. Drum filling and batching are common applications. For example, supported configurations can add weight setpoints, relays, alarms, light towers and safe-area control interfaces.
Can ArlynGuard D weigh containers other than drums?
Yes, provided the container dimensions, loaded weight and loading method suit the selected platform and capacity. If a standard 30″ or 36″ platform does not meet the application requirements, contact Arlyn Scales to discuss other options.
Configure an ArlynGuard D for Your Hazardous-Area Drum Weighing Application

Tell us the drum or container size, maximum loaded weight, hazardous-area classification and any required PLC, data, alarm or process-control functions. Arlyn Scales can then help determine the appropriate D-series model and ArlynGuard configuration.


Contact Arlyn Scales


Compare ArlynGuard Configurations


Explosive Environment Scales – ArlynGuard D

$2,409.00

Arlyn Scales

Explosive Environment Scales – ArlynGuard D

$2,409.00

Arlyn Scales